BKSGP - TEX PTFE INSULATION JACKET BRAID OR BINDER
- MSDS: BKSGP
- Manufacturer: W L GORE AND ASSOCIATES INC
- Product Name: TEX PTFE INSULATION JACKET BRAID OR BINDER
- National Stock Number: 6810-00N017466
Product Identification
Product ID:TEX PTFE INSULATION JACKET BRAID OR BINDER
MSDS Date:01/11/1991
FSC:6810
NIIN:00N017466
MSDS Number: BKSGP
Responsible Party
NEWARK, DE 19714
US
Emergency Phone: 301-392-3700
Info Phone: 302-738-4880; 602-431-0077
Cage: 60622
Contractor
Telephone: 602-431-0077
Cage: 60622
Ingredients
ETHYLENE, TETRAFLUORO-,POLYMER (POLYTETRAFLUOROETHYLENE)
CAS: 116-14-3
RTECS: KX4025000
Fraction By Weight: >97%
PIGMENT - MAY CONTAIN CADMIUM (ING 3)
RTECS: 9999999ZZ
Fraction By Weight: <3%
OSHA PEL 0.2 MG/M3 DUST (MFR)
ACGIH TLV: 0.05 MG/M3 (MFR)
CADMIUM (SARA III)
CAS: 7440-43-9
RTECS: EU9800000
OSHA PEL SEE 1910.1027
ACGIH TLV: 0.01 MG/M3 DUST;9394
EPA Report Quantity: 10 LBS
DOT Report Quantity: 10 LBS
CARBON BLACK
CAS: 1333-86-4
RTECS: FF5800000
OSHA PEL 3.5 MG/M3
ACGIH TLV: 3.5 MG/M3; 9192
CHROMIUM (SARA III)
CAS: 7440-47-3
RTECS: GB4200000
OSHA PEL 1 MG/M3
ACGIH TLV: 0.5 MG/M3; 9192
EPA Report Quantity: 1 LB
DOT Report Quantity: 1 LB
SELENIUM (SARA III)
CAS: 7782-49-2
RTECS: VS7700000
OSHA PEL 0.2 MG/M3
ACGIH TLV: 0.2 MG/M3; 9192
EPA Report Quantity: 1 LB
DOT Report Quantity: 1 LB
TITANIUM DIOXIDE
CAS: 13463-67-7
RTECS: XR2275000
OSHA PEL 15 MG/M3 TDUST
ACGIH TLV: 10 MG/M3 TDUST; 9293
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:NO CHRONIC HEALTH EFFECTS ARE
ANTICIPATED UNDER NORMAL HANDLING & USE. OVERHEATING (OVER 260C) OR
BURNING OF MATL MAY CREATE THERMAL DECOMPOSITION PRODUCTS THAT
COULD RESULT IN IRRITATION OF THE EYES, SKIN, RESPIRATORY TRACT OR
"POLYMER FUME FEVER".
Explanation of Carcinogenicity:CADMIUM AND COMPOUNDS: GROUP 2A (IARC);
GROUP 2 (NTP). CHROMIUM AND CERTAIN COMPOUNDS: GROUP 1 (IARC);
GROUP 1 (NTP).
Effects of Overexposure:INHALATION OF THERMAL DECOMPOSITION PRODUCTS
PRODUCES RESPIRATORY DIFFICULTY (INFLUENZA LIKE SYMPTOMS) WHICH MAY
NOT OCCUR UNTIL SEVERAL HOURS AFTER EXPOSURE & PASS OFF WITHIN
36-48 HRS, EVEN IN THE A BSENCE OF TREATMENT. SMOKING TOBACCO
ORCIGARETTES CONTAMINATED W/POLYMER DUST MAY CAUSE "POLYMER FUME
FEVER).
Medical Cond Aggravated by Exposure:INDIVIDUALS W/PRE-EXISTING
RESPIRATORY DISABILITY OR SKIN SENSITIVITY SHOULD BE CAUTIONED
AGAINST EXPOSURE TO THIS MATERIAL IF THERMAL DECOMPOSITION OF THIS
MATERIAL OCCURS.
First Aid
First Aid:INHAL: IF INHAL OF THERMAL DECOMP PRODS PRDCES RESP DFCLTY
(INFLUENZA LIKE SYMP) MOVE INDIVIDUAL TO FRESH AIR. CONSULT MD IF
SYMP PERSIST. IF BRTHG STOPS, GIVE ARTF RESP & SEEK MED ATTN IMMED.
SKIN: I RRIT/BURNS COULD RSLT IF CONT W/JACKET MATLS OCCURS DURING
HEATING OR THERMAL DECOMP. STD FIRST AID SHLD BE APPLIED FOR MINOR
BURNS OR IRRIT. PERSISTANT IRRIT SHOULD BE MEDICALLY TREATED. (SUPP
DATA)
Fire Fighting
Flash Point:DOES NOT FLASH
Extinguishing Media:WATER, CO*2, FOAM OR DRY CHEM. MATL DOES NOT BURN
W/O EXTERNAL FLAME. USE EXTING MEDIA APPROP FOR THE SURROUNDING
FIRE.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPRVD SCBA & FULL PROTECTIVE
EQUIPMENT .
Unusual Fire/Explosion Hazard:TOXIC FLUORINE COMPOUNDS & METAL FUMES
MAY BE EVOLVED IN FIRE.
Accidental Release
Spill Release Procedures:COLLECT BY SWEEPING OR VACUUM ANY LOOSE
MATERIAL (WIRE OR INSULATION) TO PREVENT ACCUMULATION OF PRODUCT.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:NONE SPECIFIED BY MANUFACTURER.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.
Exposure Controls
Respiratory Protection:NOT NORMALLY REQUIRED UNDER ANTICIPATED
CONDITIONS OF USE. IF NECESSARY, USE ONLY NIOSH/MSHA APPROVED
RESPIRATOR APPROPRIATE FOR EXPOSURE OF CONCERN .
Ventilation:LOCAL EXHAUST WHEN HEATING OR MELTING INSULATION AS IN
SOLDERING OR THERMAL STRIPPING.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:NONE SPECIFIED BY MANUFACTURER.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
HAZ DECOMP PROD:PERFLUOROISOBUTYLENE, CARBONYL FLUORIDE, & HYDROGEN
FLUORIDE. FIRST AID PROC: PERSISTANT IRRIT SHLD BE MED TREATED.
INGEST: IF INSULATION OR WIRE IS INGESTED, SEEK MED ATTN. DO NOT
IND UCE VOMIT. EYES: CONT W/AIRBORNE PARTICULATE REQ IMMED ATTN.
SEEK MED ASSISTANCE IF REMOVAL OF IMBEDDED MATL IS REQD.
Chemical Properties
Melt/Freeze Pt:M.P/F.P Text:>572F,>300C
Solubility in Water:INSOLUBLE
Appearance and Odor:CLEAR OR PIGMENTED INSULATION, JACKET, BRAID OR
BINDER TAPE WITH NO ODOR.
Stability
Stability Indicator/Materials to Avoid:YES
MOLTEN ALKALI METALS, INTERHALOGEN COMPOUNDS.
Stability Condition to Avoid:WILL BURN IN A ATMOSPHERE OF 95% OXYGEN
WHEN IGNITION SOURCE IS PRESENT.
Hazardous Decomposition Products:THERMAL DECOMP MAY RELEASE PARTICULATE
& GASEOUS PRODS INCLUDING: TETRAFLUOROETHYLENE,
HEXAFLUOROPROPYLENE, (SUPP DATA)
Disposal
Waste Disposal Methods:DISPOSE OF ACCUMULATED WASTE IN ACCORDANCE WITH
APPLICABLE FEDERAL, STATE AND LOCAL REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.